Model: PWM-Series
Power Supply: 3P ACA380V, 400W, 450V etc. frequency 50Hz
Rated Output DC Voltage: 12V, 15V, 18V, 24V, 36V etc any voltage specification
Rated Output DC Current: 500A, 1000A, 1500A, 2000A, 3000A, 4000A, 5000A, 6000A, 8000A, 12000A, 15000A, 18000A, 20000A etc any current specification
The product adopts 6-pulse or 12-pulse thyristor automatic reversing rectifier and mainly used as reversing rectifier power supply reversing rectification power supply to electroplate finish of all kinds of metal and nonmetal (like electroplating hard chrome and electrolytic oil-removal etc.)
- Operntion mode: local/remote operation mode can be chosen
- Operntion control mode: constant current/constant voltage output control mode can be chosen
- Operntion reversing mode: thyristor contactless reversing, one time reversing and automatically periodic reversing
- Soft start time: Working time of soft start can be set between 0-200s
- Constant current/constant voltage control accuracy: ≤±1%
- Rectifier mode: thyristor phase-shifting voltage regulation and rectifier
- Rectifier pulse number: 6 pulses or 12 pulses
- Output ripple coefficient: 6 pulse rectifier ≤5%, 12 pulse rectifier ≤3%
- Thyristor trigger controller: DSP computer digital trigger control, trigger pulse asymmetry ≤0.1°, pulse phase-shifting resolution ≤1us
- Main protection functions: lack phase, overvoltage, undervoltage, quick fuse or fuse alarm protection of AC power supply, Output overcurrent and current, limiting protection, output short circuit and instantaneous overload protection, over temperature and overheat protection of silicon controlled components, rectification transformer and bus copper bar, overheating and high pressure protection of wind machine, low block trigger pulse protection
- Communication means: CAN BUS, PROFIBUS, ETHERNET, RS485 and RS232 optical fiber communication can be chosen to realize remote control or monitor according to customers’requirements
- Rectification transformer adopts three-core five-column structure, iron core uses good quality oriented silicon steel sheet, transformer coil are all copper, no-load loss less than 2%, 8-10%power-saving comparing with common three-phase three column rectification transformer
- Remote control operation box: remote operation control cabinet can be chosen according to customer’s situation on site, hose and remote control cabinet are placed separately, the on-site operation is more convenient, anti-corrosion protection of host increased greatly
Technical Data Sample Of One Model
We can customize our Power Supply(Rectifier) as your request.
AC input | 380V±10% |
AC input power | 39.6KW |
DC input voltage | 0-12V continuously adjustable |
DC output current | 0-3000A continuously adjustable |
Out put power | 36KW |
Waving data | Waving valid values less than 3% |
Constant current, constant voltage conversion | Precision of constant current 1%, Constant pressure precision 1% |
Defensive function | Under voltage, over voltage, overload, short circuit protection, thermal protection. |
The power factor | Using active power factor is positive, full range 0.95 |
Insulation resistance | >10mΩ |
Power DC protection time | More than 20msec |
Overload protection | 105~120% Rated output current |
Short-circuit protection | Instantaneous short-circuit |
Working frequency | 28KHz |
Operating temperature range | -20℃~50℃ |
Type of cooling | Air-cooling |
Dimensions (L * W * H)mm | 600*520*858 |